2 3QGD
2QG
2: Well diameter: 100mm(2")
QG : Pump name
D:Single motor(Three phase without D)
1:Capacity(m3/h)
48: Heab(m)
0.25:Motor power(KW)
For water supply from wells or reservoirs.
For domestic use, for civil and industrial applications.
For garden use and irrigation.
Maximum fluid temperature up to +35 °C.
Maximum sand content: 0.25%.
Maximum immersion: 100m.
Minimum well diameter: 2", 3".
Rewindable motor or Full obturated screen motor
Three-phase: 380V-415V/50Hz
Single-phase: 220V-240V/50Hz
Equip with start control box or digital auto-control box
Pumps are designed by casing stressed
NEMA dimension standards
Special mechanical seal
Other voltages or frequency 60 Hz
SIZE PARATEMER TABLE | |||||
MODEL | A | B | C | D | E |
2QGD1-48-0.25 | 688 | 520 | 168 | 0.5" | Φ52 |
3QGD1.5-72-0.37 | 580 | 385 | 195 | 1" | Φ75 |
3QGD1.5-90-0.55 | 610 | 415 | 195 | 1" | Φ75 |
3QGD2-103-0.75 | 652 | 445 | 207 | 1" | Φ75 |
MODEL | P2 | DELIVERY n=2850 l/min | ||||||||
1~220v/240v | KW | HP | Q | l/min | 0 | 4 | 6 | 10 | 13 | 17 |
m3/h | 0 | 0.2 | 0.4 | 0.6 | 0.8 | 1 | ||||
2QGD1-48-0.25 | 0.25 | 0.33 | H(m) | 48 | 30 | 21 | 14 | 7 | 1 |
MODEL | P2 | DELIVERY n=2850 l/min | ||||||||||
1~220v/240v | KW | HP | Q | l/min | 0 | 5 | 8 | 13 | 17 | 20 | 25 | 33 |
m3/h | 0 | 0.3 | 0.5 | 0.8 | 1 | 1.2 | 1.5 | 2 | ||||
3QGD1.5-72-0.37 | 0.37 | 0.5 | H(m) | 72 | 52 | 42 | 28 | 24 | 11 | 1 | ||
3QGD1.5-90-0.55 | 0.55 | 0.75 | 90 | 72 | 60 | 44 | 32 | 18 | 1 | |||
3QGD2-103-0.75 | 0.75 | 1.0 | 103 | 84 | 75 | 60 | 49 | 43 | 27 | 1 |
2QG
2: Well diameter: 100mm(2")
QG : Pump name
D:Single motor(Three phase without D)
1:Capacity(m3/h)
48: Heab(m)
0.25:Motor power(KW)
For water supply from wells or reservoirs.
For domestic use, for civil and industrial applications.
For garden use and irrigation.
Maximum fluid temperature up to +35 °C.
Maximum sand content: 0.25%.
Maximum immersion: 100m.
Minimum well diameter: 2", 3".
Rewindable motor or Full obturated screen motor
Three-phase: 380V-415V/50Hz
Single-phase: 220V-240V/50Hz
Equip with start control box or digital auto-control box
Pumps are designed by casing stressed
NEMA dimension standards
Special mechanical seal
Other voltages or frequency 60 Hz
SIZE PARATEMER TABLE | |||||
MODEL | A | B | C | D | E |
2QGD1-48-0.25 | 688 | 520 | 168 | 0.5" | Φ52 |
3QGD1.5-72-0.37 | 580 | 385 | 195 | 1" | Φ75 |
3QGD1.5-90-0.55 | 610 | 415 | 195 | 1" | Φ75 |
3QGD2-103-0.75 | 652 | 445 | 207 | 1" | Φ75 |
MODEL | P2 | DELIVERY n=2850 l/min | ||||||||
1~220v/240v | KW | HP | Q | l/min | 0 | 4 | 6 | 10 | 13 | 17 |
m3/h | 0 | 0.2 | 0.4 | 0.6 | 0.8 | 1 | ||||
2QGD1-48-0.25 | 0.25 | 0.33 | H(m) | 48 | 30 | 21 | 14 | 7 | 1 |
MODEL | P2 | DELIVERY n=2850 l/min | ||||||||||
1~220v/240v | KW | HP | Q | l/min | 0 | 5 | 8 | 13 | 17 | 20 | 25 | 33 |
m3/h | 0 | 0.3 | 0.5 | 0.8 | 1 | 1.2 | 1.5 | 2 | ||||
3QGD1.5-72-0.37 | 0.37 | 0.5 | H(m) | 72 | 52 | 42 | 28 | 24 | 11 | 1 | ||
3QGD1.5-90-0.55 | 0.55 | 0.75 | 90 | 72 | 60 | 44 | 32 | 18 | 1 | |||
3QGD2-103-0.75 | 0.75 | 1.0 | 103 | 84 | 75 | 60 | 49 | 43 | 27 | 1 |